FXR-75 |
| | |
![]() The FXR-75 - Full View - Looking at beam port | ![]() Closeup of Beam Port & Installation of test sample | ||
| Type of Simulator | Flash x-ray | ||
|---|---|---|---|
| Application | X rays, electrons for TREE, material response | ||
| Test Object Size |
4 cm2 e-beam 1 m2 x-ray | ||
| General Description | The facility has dedicated screen rooms, diagnostics and associated general purpose test equipment, and technical support personnel. | ||
| Technical Characteristics | Voltage | ||
| x-ray mode | 3 to 6.5 MV | ||
| e-beam mode | 3 to 6.5 MV | ||
| Energy | 5 to 15 kJ (3-9 delivered) | ||
| Energy | |||
| x-ray mode | 1.3 to 1.75 MeV | ||
| e-beam mode | up to 4.2 MeV | ||
| Beam Current | up to 120 kA | ||
| Fluence | 1 to 170 cal/cm2 (3 MeV average fluence with 1-inch diameter e-beam) | ||
| Dose | 15 krad(Si) | ||
| Dose rate | |||
| x-ray mode | 5(10)11 rad(Si)/s | ||
| e-beam mode | > 1(10)12 rad(Si)/s | ||
| Rise time (10-90%) | < 2 ns | ||
| Pulse width (FWHM) | 35 ns | ||
| Target area (max) | 176 cm2 | ||
| Repetition rate | 30 to 40 /hr | ||
| Reproducibility | 5% | ||
| BREL Homepage | Simulators | Capabilities | Instrumentation | Published Papers | Available Data | Who To Contact |