Boeing Radiation Effects Laboratory Associated Products Boeing Home

Linear Accelerator (LINAC)



The Control Room Console

The Accelerator

Beam Port/Experimental Area
Type of Simulator Electron linear accelerator
Application Bremsstrahlung x-rays
Electron
Test Object Size Test area will accommodate nearly any size or configuration
General Description The 3-stage S-band linear accelerator can produce stable and high-current pulses of electrons for TREE testing.

Vacuum chambers are available.

Converters can be used to produce pulses of x-rays. A remotely operated sample changer is available for rapid characterization of a large number of parts.

Technical Characteristics Energy
x-ray 1.7 to 3.3 MeV
Electron 5.0 to 30 MeV (10 MeV Standard)
Current 0.4 to 2 amps (depending upon pulse width)
Dose 600 krad(Si) (max per pulse)
Doserate
x-ray 5.0 Mrad(Si)/s
Electron 1.0(10)11 rad(Si)/s (max)
Pulse Width (FWHM) 10ns to 10us
Target Area Variable up to several inches/side
Repetition Rate 0 to 30 Hz
Reproducibility 5%

BREL Homepage | Simulators | Capabilities | Instrumentation | Published Papers | Available Data | Who To Contact